• Thermostat Viscometer
  • DHJ-5S+DH-0506N
  • Measurement range: 1 ~ 1×100000 mPa.s, temperature control range: -5℃ ~ 100℃.
  • DHJ-5S+DH-0506N
  • Thermostat Viscometer
  • Measurement range: 1 ~ 1×100000 mPa.s, temperature control range: -5℃ ~ 100℃.
When the temperature deviation is 0.5℃, the viscosity of some liquids deviates by more than 5%. Temperature deviation has a significant impact on viscosity, as viscosity decreases with increasing temperature. Therefore, special attention should be paid to keeping the temperature of the measured liquid constant near the specified temperature point, and for accurate measurement, it is best not to exceed 0.1℃. To this end, our company specializes in producing constant temperature cups and constant temperature baths for use with the DHJ series viscometer.
Product Introduction
When the temperature deviation is 0.5℃, the viscosity of some liquids deviates by more than 5%. Temperature deviation has a significant impact on viscosity, as viscosity decreases with increasing temperature. Therefore, special attention should be paid to keeping the temperature of the measured liquid constant near the specified temperature point, and for accurate measurement, it is best not to exceed 0.1℃. To this end, our company specializes in producing constant temperature cups and constant temperature baths for use with the DHJ series viscometer.


Product Features
This instrument is a digital viscosity meter, driven by a motor through a variable speed belt to rotate the rotor at a constant speed. When the rotor rotates in the liquid, the viscosity of the liquid produces a corresponding viscosity torque on the rotor, which increases with increasing viscosity and decreases with decreasing viscosity. The viscosity torque acting on the rotor is detected by a sensor and the viscosity of the measured liquid is calculated by a computer after processing the data.
This instrument uses microcomputer technology, which can easily set the measuring range (rotor number and speed), digitally process the data detected by the sensor, and display the set rotor number, speed, viscosity value, and full-scale percentage value of the measured liquid clearly on the display screen.
NDJ-8S is equipped with 4 rotors (No. 1, 2, 3, and 4) and 8 speed levels (0.3, 0.6, 1.5, 3, 6, 12, 30, and 60 rpm), which can be combined into 32 different combinations to measure the viscosity of various liquids within the specified range.
The DH-0506N constant temperature device can control the sample temperature within the range of -5℃ to 100℃.


Technical Specifications    
Model: DHJ-5S DH-0506N
Measurement Range: 1 ~1×105mPa.s /
Rotor Specifications: rotors 1-4, optional rotor 0 for low viscosity measurement down to 0.1mPa.s /
Rotor Speed: 3, 6, 12, 30, 60 rpm /
Automatic Mode: Automatically selects suitable rotor and speed /
Display Language: Chinese/English /
Stable Reading Indicator: Vertical bar cursor indicates when the reading is basically stable at full scale /
Measurement Accuracy: ±2% (Newtonian fluids) /
Power Supply: AC 220V±10% 50Hz±10% /
Operating Environment: Temperature 5℃~35℃, relative humidity not exceeding 80% /
Dimensions: 370*325*280mm 430*410*420mm
Net Weight: 6.8kg 23.5kg
Temperature Range: / -5~100(℃)
Temperature Fluctuation: / ±0.05(℃)
Temperature Control Mode: / Microcomputer temperature control, PID adjustment
Display Resolution: / 0.01(℃)
Inner Chamber Volume: / 8(L)
Inner Slot Size: / 270*160*185(length*width*depth)(mm)
Opening Size(Diameter): / Φ75(mm)
Pump Circulation Mode: / Internal/External circulation
Pump Flow Rate: / 8(L)
Cooling Method: / Compressor refrigeration


Notes
1. The constant temperature bath should be placed on a sturdy workbench;
2. No vibration or harmful gases should be present;
3. The ambient temperature should be relatively stable and not fluctuate too much, otherwise it will affect the temperature control accuracy. The ambient temperature should be around 25℃, especially for constant temperature baths at -40℃, -65℃, and -80℃. High ambient temperatures can affect the heat dissipation of the compressor, reduce refrigeration efficiency, and easily cause malfunctions;
4. The constant temperature bath should be regularly maintained, especially if the cooling speed slows down after a period of operation. The plastic grid plate of the constant temperature bath should be removed to clean the dust from the compressor and heat sink.
 
 


Single Page - Color Page    
Name: Author: Action:
Thermostat Viscometer    DHJ-5S+DH-0506N Viscometer Download

 

 

Product List
DHJ-5S+DH-0506N Unit
Host Machine Unit
Rotor 1-4 set
Rotor 0 set
Protective cover unit
Base unit
Lifting column set
A pair of pliers (one large and one small) set
Hexagonal socket head piece
Power adapter set
User manual copy
Warranty card copy
Certificate of qualification copy
Description
1
1
Optional
1
1
1
2
1
1
1
1
1